热电偶测温原理及其焊接

2010-12-248200

                      
       四、热电偶的焊接

IEC要求

4.0 PROCEDURES(见图6.3)
4.1 Thermocouples shall be prepared by staff trained in preparation of thermocouples.
4.2 Thermocouples are to be prepared as noted:
4.2.1 Inner insulation stripped back approximately 1.5 mm from tip.
4.2.2 Outer insulation, if any, stripped back approximately 15 mm from
tip.
4.2.3 The tip is to be joined by a single          point weld. Other reliable and consistent methods of joining the thermocouple wires may be used upon prior acceptance
of the CTL.
Note – Dimensions given are typical, not required.
即要求:露出金属端为1.5mm,  剥掉外层绝缘为15mm

图6.3热电藕焊点要求

焊接

(大众版) 电容焊借助于一组并联的电容(其容量约在2000~3000μF,电压在50V以下)经验值是20000μF。在放电的瞬间产生火花使电偶丝熔接在一起,形成球状的焊点,如图6.4所示

 
图6.4自制电藕焊接装置

在输入供电30Vdc左右的情况下, 用镊子夹住热电藕的一头(包含两根线)去接触金属块。即可, 接触时请闭眼。

1. 石墨电炉焊接(专业版)
焊接设备线路如图6.5所示。它由自耦变压器、石墨电炉及连接导线组成。将两根不同的热电极丝用砂纸去掉表面氧化物,焊接端扭成麻花状,端部剪齐,把两根电极丝夹紧在由与地端相连的引出线的夹子上,转动自耦变压器手轮,使自耦变压器的输出电压在35伏左右,而后将电极丝插入石墨粉内,由于短路产生的电弧使两根热电极丝插入端熔结。

图6.5 石墨电炉焊接线路图

焊接时要注意掌握插入时间,若时间太长,熔结点会因电极丝继续熔化而掉落,并增加氧化;时间太短,则因电极丝未熔化而没有熔结。自耦变压器的输出电压,应根据焊接时的具体情况作适当调整。

« 上一页 2/4 下一页 »
收藏 0
打赏 0
评论 0
如何测量热电偶测量温度?
温度和热电偶概述 温度是对物体样本中粒子平均动能的测量方式,其标准单位是度。温度可以通过不同方法进行测量,测量的成本和精确度也因此各不相同。热电偶就是其中一种常见的测量温度的传感器,因为热电偶相对而言

0评论2014-11-04426

变压器温升测量热电偶法与热电电阻法的比较
  在设备中,变压器作为安全件有着极其重要的作用。如果设备在正常工作或局部产生故障的情况下,而引起变压器温升过高且已超出变压器材料件(如骨架.线包.漆层等)所能承受的温度,可能会使变压器绝缘失效,引起触电危险

0评论2008-11-171021

热电阻和热电偶的测量原理及区别
热电偶是工业上最常用的温度检测元件之一。其优点是:①测量精度高。因热电偶直接与被测对象接触,不受中间介质的影响。②测量范围广。常用的热电偶从-50~+1600℃均可边续测量,某些特殊热电偶最低可测到-269℃(如

0评论2007-08-05556

热电偶焊接的一般要求及温度曲线测试方法
 摘 要:介绍了再流焊机的一般技术要求,并给出了典型焊接温度曲线以及温度曲线上主要控制点的工艺参数。 关键词:温度曲线;预热区;焊接区;冷却区;预热温度;焊接峰值温度   再流焊接是表面组

0评论2005-10-20944