本文导读:直插式电源适配器申请UL 1310 Class 2 unit 须注意下述二项要求: 1、 若包含CUL依据CSA标准 CAN/CSA-C22.2 NO.233-M91 章节 4.13.1 Open-Circuit Secondary Voltage The open-circuit secondary voltage shall not

直插式电源适配器申请UL 1310 Class 2 unit 须注意下述二项要求:
 
       1、 若包含CUL 

依据CSA标准 CAN/CSA-C22.2 NO.233-M91 章节 4.13.1 Open-Circuit Secondary Voltage “The open-circuit secondary voltage shall not be more than 30Vrms (42.2V peak or DC) ” 

2、 间距要求,依条文22.1, 22.2如下
 
22.1 Spacings between live parts of opposite polarity, between live and dead metal parts, and between live parts and a metal enclosure, shall be as specified in Table 22.1 or Table 22.2, as appropriate. If a live part is not rigidly secured in position by a means other than friction between surfaces, or if a movable dead metal part is in proximity to an uninsulated live part, the construction shall be such that at least the minimum spacings will be maintained. 

Exeption No.1: Spacings between traces on a printed wiring board need not comply with Tables 22.1 and 22.2 if the printed wiring board complies with the abnormal operation test in 38.7.1 – 38.7.5. See also 20.3. The requirements specified in 20.3 and 38.7.1 – 38.7.5 do not substitute for the minimum requied spacings between the printed wiring board foils and dead metal parts or the spacings between the primary and secondary foils of the printed wiring board as specified in Table 22.1 or 22.2. 

 
收藏 0打赏 0评论 1
免责声明:凡注明来源本网的所有作品,均为本网合法拥有版权或有权使用的作品,欢迎转载,注明出处。非本网作品均来自互联网,转载目的在于传递更多信息,并不代表本网赞同其观点和对其真实性负责。
 
更多>相关阅读
推荐图文
推荐安规
阅读排行
点赞排行
网站首页
网站介绍
版权声明
积分规则
服务协议
隐私政策
网站服务
广告服务
会员服务
排名推广
定制推广
积分换礼

RSS订阅
网站留言
网站地图
违规举报

微信公众号

联系我们
苏州市姑苏区三香路979号中翔经贸大楼7楼
服务电话:0512-68157565
客服热线:17314226061
电子邮件:service@lairuice.com